ThermoCube Air-Cooled Liquid Recirculating Chiller in 265 Capacities
for laboratory
high ambient coolng needs
analytical
and other applications with modest heat loads
Examples of Current Customer Applications
chemical reagent cooling
laser hair removal
laser tatoo removal
Download PDF Brochure
Why choose ThermoCube 265?
Compact size: 12.75 x 11 x 12.75"”
Precise temperature control ( +0.05 °C) even near ambient
For use with water/glycol solutions, water/alcohol, Fluorinert or HFE or water
Very energy efficient (typically <300 W AC)
Whisper-quiet, 63 dBA
Worldwide power compatibility, universal input standard
Easy-to-use controller for fixed temperature control or temperature cycling
Air-cooled. Does not require house or facility chilled water. Can operate in any standard room, laboratory or office.
Benefits of The ThermoCube 265 Recirculating Chiller
Reliable Freon-Free Thermoelectric Technology
The ThermoCube uses thermoelectric technology, widely used throughout the world for 50 years in various applications from spacecrafts to home appliances. With lifetimes exceeding 200,000 hours, the thermoelectric modules at the core of this chiller make for ultra-high intrinsic reliability.
Optimized for Modest Heat Loads
ThermoCube is available in 265 Watt capacities, below the economical range of refrigerant-based chillers.
Whisper Quiet
With only two moving parts, the pump and cooling fan, ThermoCube is quiet. The 265 model runs at 63 dBA. (Liquid-cooled ThermoCubes have no fan.)
Precise Temperature Control
Because electrons transfer the heat, ThermoCube responds instantaneously to changes in load. The digital PID temperature controller holds to < + 0.05 °C, even near ambient.
Energy Efficiency
ThermoCube is very energy-efficient. Its thermoelectric modules are powered by a variable voltage power supply that provides the minimum power required to control the temperature at set point, so ThermoCube only draws as much power as needed. It was also designed to operate in the modules’ most energy-efficient range.
No Vibration
ThermoCube provides virtually vibration-free liquid flow when equipped with smooth-flow gear pumps and external filter.
High Pressure Pumps Standard
ThermoCube’s standard pump is capable of delivering up to 50 psi for laser diode and other high-pressure applications.
A ThermoCube 265 is shown with a regulation-size soccer ball for comparison.
All ThermoCubes are the same size.
ThermoCube Front User Interface Panel
| Operating Range: |
-15 to 65 °C standard range
|
Noise |
63 dBA at 3 feet
(60 or 49 dBA optional) |
| Cooling Capacity: |
265 W at
25 °C (25 °C ambient)
See performance curve
|
Size (L x W x H): |
12.75 x 11.0 x 12.75"
(32.4 x 28 x 32.4 cm) |
| Modes: |
Fixed setpoint, cycling |
Weight: |
28 lbs. (12.7 kg)
(with basic options)
|
| Precision: |
< + 0.05 °C, even near ambient |
Standards: |
CE, Intertek listed
to ANS/UL STD 61010-1
|
| Coolant: |
Water/glycol mixture, Galden/Fluorinert, or HFE
|
Pumps: |
See Pump Curves under
Performance
|
| Power: |
85-265 VAC, 50 or 60 Hz |
Warranty:
|
2 years |
| Alarms: |
TTL (temp and system failure), fluid level |
|
|
Capacity
Pumps
| Option |
Purpose |
Noise |
Pressure |
Allowed Process Coolant |
MTBF (manufacturer's) |
Pump Warranty* |
1 lpm magnetic drive gear
|
smooth flow, virtually vibration free, stainless steel head allows additional process fluids |
63 dBA |
3 bar, 40 psi |
Water, glycol/water, alcohol/water, DI water, HFE, PAO, Fluorinert, Galden |
25,000 hr MTBF
|
2 yr |
2 lpm magnetic drive gear
|
smooth flow, virtually vibration free, stainless steel head allows additional process fluids |
65 dBA |
3 bar, 40 psi |
Water, glycol/water, alcohol/water, DI water, HFE, PAO, Fluorinert, Galden |
25,000 hr MTBF |
2 yr
|
| 3 lpm magnetic drive gear |
smooth flow, virtually vibration free, stainless steel head allows additional process fluids |
|
3 bar, 40 psi |
Water, glycol/water, alcohol/water, DI water, HFE, PAO, Fluorinert, Galden |
25,000 hr MTBF |
2 yr |
Fans
All fans suitable for indoor, non-condensing environments
| Option |
Purpose |
Noise at 1 meter |
| Standard fan |
Included in base price |
60 to 63 dBA |
Power Cords
| Options |
| United States & Canada |
|
Europe
|
| Japan |
| United Kingdom |
| Israel |
| Australia |
| Isreal |
| Korea |
| China |
Customer specifies power cord for their country. Six standard cords are available at no extra charge. Universal input, 85 - 265 VAC, 50/60 Hz.
Fittings
All options are available on process coolant lines or house water lines.
| Option |
purpose |
tubing size |
manufacturer's website |
|
| John Guest |
simple, push-in fittings for plastic tubing |
1/4" |
www.johnguest.com |
|
| CPC |
valved fitting; for easy disconnect and reconnect (not recommended for use with centrifugal pump due to low head pressure) |
1/4" |
www.colder.com
|
A mating fitting must match Colder Products part number PLCD16004 |
| CPC metal |
toughened version of CPC fitting, chrome-plated brass |
1/4" |
|
A mating fitting must match Colder Products part number LCD16004 |
| Swagelok |
for use with stainless steel tubing, typically semiconductor applications, very durable |
1/4" |
www.swagelok.com |
|
Other Options
| Communications |
ES |
RS232 interface controller, enhanced on ThermoCube as of September 2007 |
| Filters |
EF |
External filter, 5 micron,
attaches to chiller externally, adds approx 6" to depth
compatible with PAO, water, glycol/water, alcohol/water, DI water
|
| |
AF |
External air filter
mounted onto fan intake grill, adds 1/2" to width of chiller
helps eliminate hair, carpet fibers, lint, dust
|
| Steel Tank |
SS |
Stainless steel tank and stainless steel plumbing |
| |
ST |
Stainless steel tank and multilayer rubber hose plumbing |
| Fixed Setpoint |
PT |
Preset control temperature from -5 to +65
No user input buttons on user interface
Fixed single setpoint
|
| Vibration Reduction |
VD |
Adds sound dampening material to interior of sheet metal skins
Useful for ultra-sensitive SEMS and CCD applications to minimize vibration traveling into fluids
|
| Dry Contact Signals |
DC |
Dry contact alarm signals |
| Auto-restart |
AR |
Software upgrade
Upon chiller power-up, unit automatically returns to control at last setpoint temperature (no operator input required)
|
| Optional Fluid Compatibility |
DI |
Electroless nickel coating on all wetted metal parts |
| |
ZZ |
Options are automatically selected to provide compatiblity with the fluid, ZZ=use one of these fluid codes
Choices: PA = PAO
SI=Silicon Oil
FL=Fluorinert
GA=Galden
|
| Custom Engineered Special |
YY |
Need-specific customization. Examples include
flow switches, custom software, remote temperature probe, custom pumps
|
|