ThermoCube 400L or 600L Liquid to Liquid Recirculating Chiller
for semiconductor fabs
or laboratories with recirculating house chilled water
Examples of Current Customer Applications
semiconductor wafer temperature control
laser cooling
gas bottle temperature control
scanning electron microscopes

Download PDF Brochure
Request Quote for 400L
Why choose ThermoCube 400L or 600L?
See the ThermoCube Model Comparison Table
Compact size: just 12” (30 cm) on a side
Precise temperature control (+0.05 °C) even near ambient
For use with fluorinert, glycol solutions or water
Very energy efficient (typically <200 W AC)
Whisper-quiet (as low as 49 dBA)
Worldwide power compatibility, universal input standard
Easy-to-use controller for fixed temperature control or temperature cycling
Excellent for manufacturing, cleanroom and laboratories
Liquid-cooled. For use with recirculated filtered treated industrial water
Benefits of the ThermoCube 400L or 600L Liquid to Liquid Recirculating Chiller
Reliable Freon-Free Thermoelectric Technology
The ThermoCube uses thermoelectric technology, widely used throughout the world for 50 years in various applications from spacecrafts to home appliances. With lifetimes exceeding 200,000 hours, the thermoelectric modules at the core of this chiller make for ultra-high intrinsic reliability.
Optimized for Modest Heat Loads
The ThermoCube L models are available in a 400 or 600-Watt capacity, below the economical range of refrigerant-based chillers and only one-fourth the size.
Whisper Quiet
With only one moving part, the pump, ThermoCube is quiet. Available with sound dampening insulation, the quietest model runs at < 50 dBA.
Precise Temperature Control
Because electrons transfer the heat, ThermoCube responds instantaneously to changes in load. The digital PID temperature controller holds to < + 0.05 °C, even near ambient.
Energy Efficiency
ThermoCube is very energy-efficient. Its thermoelectric modules are powered by a variable voltage power supply that provides the minimum power required to control the temperature at set point, so ThermoCube only draws as much power as needed. It was also designed to operate in the modules’ most energy-efficient range.
No Vibration
ThermoCube provides virtually vibration-free liquid flow when equipped with smooth-flow gear or centrifugal pumps and external filter.
High Pressure Pumps Standard
ThermoCube’s standard pump is capable of delivering up to 50 psi for laser diode and other high-pressure applications. Low-pressure pumps are also available.
A ThermoCube 300 is shown with a regulation-size soccer ball for comparison.
The ThermoCubes are the same size.
ThermoCube Front User Interface Panel
| Operating Range: |
-10 to 50 °C standard range
(down to -5 °C with low temp option)
(up to 65 °C with high temp option)
|
Process Fittings: |
1/4" John Guest standard,
CPC or Swagelok available |
| Cooling Capacity: |
400 or 600 Watts at 20 °C into 20 °C
house chilled water
See Performance Curves
|
House Fittings: |
3/8” John Guest standard,
CPC or Swagelok |
| Modes: |
Fixed setpoint, cycling |
Noise: |
48 dBA at 3 feet |
| Precision: |
< + 0.05 °C, even near ambient |
Size (L x W x H): |
12.75 x 11.0 x 12.75"
(32.4 x 28 x 32.4 cm) |
| Coolant: |
Water/glycol mixture, industrial water,
DI water or Galden with optional pump
|
Weight: |
22 lbs. (10 kg)
(with basic options) |
House water:
|
1 gpm recirculated filtered
treated industrial water
|
Standards: |
CE, Intertek listed
to ANS/UL STD 61010-1
|
Power:
|
85-265 VAC, 50 or 60 Hz
|
Pumps: |
See Pump Curves under
Performance
|
Filter:
|
Optional 5 μm external fluid filter |
Warranty: |
2 years |
| Alarms: |
TTL (temp and system failure), fluid level |
|
|
The robust and reliable ThermoCube Recirculating Chiller/Circulators are available in a range of models, including
- air-cooled
- liquid-cooled
- PAO compatible
- compressed gas temperature control, and
- air cooled enclosure cooling
Capacity
| Options |
Purpose |
Standard Operating Temperature Range |
Standard Operating Temperature Range |
| 200 W |
compact, whisper-quiet recirculating liquid chiller, cooled by ambient room air, for up to 200 W (680 BTU/hr) heat load |
5 to +50 °C |
41 to 122 °F |
| 300 W |
same as above, for up to 300 W (1020 BTU/hr) |
5 to +50 °C |
41 to 122 °F |
| 400 W |
same as above, for up to 400 W (1360 BTU/hr) |
5 to +50 °C |
41 to 122 °F |
| 400 L |
recirculating liquid chiller, cooled by house chilled water heat load up to 400 W (1360 BTU/hr) |
5 to +50 °C |
41 to 122 °F |
| 600 L |
|
|
|
| 300 A |
Temperature control of compressed inert gases, heat load up to 300 W (1020 BTU/hr) |
5 to +50 °C |
41 to 122 °F |
| 400 AC |
Enclosure air conditioner, for up to 400 W (1360 BTU/hr) |
5 to +50 °C |
41 to 122 °F |
Pumps
| Option |
Purpose |
Noise |
Pressure |
Allowed Process Coolant |
MTBF (manufacturer's) |
Pump Warranty* |
| 1 lpm diaphragm |
high pressure, quiet pulse-flow pump |
35 dBA |
3 bar, 35 psi |
Water, glycol/water, alcohol/water, DI water |
13,000 hr MTBF |
1yr |
| 2 lpm diaphragm |
for up to 2 lpm flow rates |
40 dBA |
40 psi |
Water, glycol/water, alcohol/water, DI water |
13,000 hr MTBF |
1 yr |
3 lpm diaphragm
|
for up to 3 lpm flow rates |
45 dBA |
45 psi |
Water, glycol/water, alcohol/water, DI water |
13,000 hr MTBF |
1 yr |
1 lpm magnetic drive gear
|
smooth flow, virtually vibration free, stainless steel head allows additional process fluids |
63 dBA |
3 bar, 40 psi |
Water, glycol/water, alcohol/water, DI water, HFE, PAO, Fluorinert, Galden |
25,000 hr MTBF
|
2 yr |
2 lpm magnetic drive gear
|
smooth flow, virtually vibration free, stainless steel head allows additional process fluids |
65 dBA |
3 bar, 40 psi |
Water, glycol/water, alcohol/water, DI water, HFE, PAO, Fluorinert, Galden |
25,000 hr MTBF |
2 yr
|
| 1-2 lpm centrifugal |
smooth flow, virtually vibration free, low pressure pump |
|
1 bar (15 psi) |
Water, glycol/water, alcohol/water, DI water |
25,000 hr MTBF |
2 yr
|
*ThermoCube chiller warranty is 2 yrs, however diaphragm pumps only carry a 1 yr warranty
Pump Curves can be seen by clicking the Performance tab above
Fans
All fans suitable for indoor, non-condensing environments
| Option |
Purpose |
Noise at 1 meter |
| Standard fan |
Included in base price |
60 to 63 dBA |
| Quiet fan |
Quieter, constant speed operation |
57 to 60 dBA |
| Variable speed fan |
Variable speed operation, normal mode at 49 dBA and will increase fan speed as needed to meet setpoint |
49 to 60 dBA |
|
|
|
Power Cords
| Options |
| United States & Canada |
|
Europe
|
| Japan |
| United Kingdom |
| Israel |
| Australia |
Customer specifies power cord for their country. Six standard cords are available at no extra charge. Universal input, 85 - 265 VAC, 50/60 Hz.
Fittings
All options are available on process coolant lines or house water lines.
| Option |
purpose |
tubing size |
manufacturer's website |
|
| John Guest |
simple, push-in fittings for plastic tubing |
1/4" |
www.johnguest.com |
|
| CPC |
valved fitting; for easy disconnect and reconnect (not recommended for use with centrifugal pump due to low head pressure) |
1/4" |
www.colder.com
|
A mating fitting must match Colder Products part number PLCD16004 |
| CPC metal |
toughened version of CPC fitting, chrome-plated brass |
1/4" |
|
A mating fitting must match Colder Products part number LCD16004 |
| Swagelok |
for use with stainless steel tubing, typically semiconductor applications, very durable |
1/4" |
www.swagelok.com |
|
Other Options
| Communications |
RS232 interface controller, enhanced on ThermoCube as of September 2007 |
| Filters |
External filter, 5 micron,
attaches to chiller externally, adds approx 6" to depth
compatible with PAO, water, glycol/water, alcohol/water, DI water
|
| |
External air filter
mounted onto fan intake grill, adds 1/2" to width of chiller
helps eliminate hair, carpet fibers, lint, dust
|
| Fixed Setpoint |
Preset control temperature from -5 to +65
No user input buttons on user interface
Fixed single setpoint
|
| Extended temperature range |
Extends lower range to -5 °C (23 °F) |
| |
Extends upper range to 65 °C (149 °F) |
| Vibration Reduction |
Adds sound dampening material to interior of sheet metal skins
Useful for ultra-sensitive SEMS and CCD applications to minimize vibration traveling into fluids
|
| Dry Contact Signals |
Dry contact alarm signals |
| Auto-restart |
Software upgrade
Upon chiller power-up, unit automatically returns to control at last setpoint temperature (no operator input required)
|
| Optional Fluid Compatibility |
Electroless nickel coating on all wetted metal parts |
| |
Options are automatically selected to provide compatiblity with the fluid
Choices: PA = PAO
SI=Silicon
FL=Fluorinert
GA=Galden
|
| Custom Engineered Special |
Need-specific customization. Examples include
flow switches, custom software, remote temperature probe, custom pumps
|
|